Title
Cyclic behavior of Peruvian confined masonry walls and calibration of numerical model using genetic algorithms
Date Issued
15 September 2014
Access level
metadata only access
Resource Type
journal article
Author(s)
Publisher(s)
Elsevier B.V.
Abstract
The experimental results of four full-scale confined masonry (CM) walls subjected to cycling loading are presented. These structural elements are widely used in low- and mid-rise buildings in Peru to take the vertical and lateral loads. The objective of these experiments was to evaluate the cyclic behavior of CM walls constructed with handmade bricks and lime mortar. The brick units used in the walls were made of clay, and they were considered to be solid components. In the experiment, the dimensions of all the walls were kept constant in all specimens, but the reinforcement ratios of the confining elements (bond beam and tie-columns) were changed. The structural behaviors were examined in terms of the strength, lateral stiffness, dissipated energy, and equivalent viscous damping. Finally, an equivalent macro-model based on an equivalent strut approach with a smooth hysteretic model was calibrated and validated in order to reproduce the behaviors of the CM walls. For this purpose, we used a genetic algorithm (GA) that considered the experimental results of a CM wall. The parameters were applied to the results of the other CM walls to evaluate their applicability. The results of numerical simulations showed good agreement with the experimental results. © 2014 Elsevier Ltd.
Start page
561
End page
576
Volume
75
Language
English
OCDE Knowledge area
Ingeniería civil
Subjects
Scopus EID
2-s2.0-84904126456
Source
Engineering Structures
ISSN of the container
01410296
Sources of information:
Directorio de Producción Científica
Scopus