A systematic review of the utility of 1.5 versus 3 Tesla magnetic resonance brain imaging in clinical practice and research
Date Issued
01 November 2012
Access level
metadata only access
Resource Type
review
Author(s)
Wardlaw J.M.
Brindle W.
Casado A.M.
Shuler K.
Henderson M.
Thomas B.
MacFarlane J.
Maniega S.M.
Lymer K.
Morris Z.
Pernet C.
Nailon W.
Ahearn T.
Mumuni A.N.
McLean J.
Chakirova G.
Tao Y.
Simpson J.
Stanfield A.C.
Johnston H.
Parikh J.
Royle N.A.
De Wilde J.
Bastin M.E.
Weir N.
Farrall A.
Hernandez M.C.V.
University of Dundee
Abstract
Objective MRI at 3 T is said to be more accurate than 1.5 T MR, but costs and other practical differences mean that it is unclear which to use. Methods We systematically reviewed studies comparing diagnostic accuracy at 3 T with 1.5 T. We searched MEDLINE, EMBASE and other sources from 1 January 2000 to 22 October 2010 for studies comparing diagnostic accuracy at 1.5 and 3 T in human neuroimaging. We extracted data on methodology, quality criteria, technical factors, subjects, signal-to-noise, diagnostic accuracy and errors according to QUADAS and STARD criteria. Results Amongst 150 studies (4,500 subjects), most were tiny, compared old 1.5 T with new 3 T technology, and only 22 (15 %) described diagnostic accuracy. The 3 T images were often described as "crisper", but we found little evidence of improved diagnosis. Improvements were limited to research applications [functional MRI (fMRI), spectroscopy, automated lesion detection]. Theoretical doubling of the signal-to-noise ratio was not confirmed, mostly being 25 %. Artefacts were worse and acquisitions took slightly longer at 3 T. Conclusion Objective evidence to guide MRI purchasing decisions and routine diagnostic use is lacking. Rigorous evaluation accuracy and practicalities of diagnostic imaging technologies should be the routine, as for pharmacological interventions, to improve effectiveness of healthcare. Key Points • Higher field strength MRI may improve image quality and diagnostic accuracy. • There are few direct comparisons of 1.5 and 3 T MRI. • Theoretical doubling of the signal-to-noise ratio in practice was only 25 %. • Objective evidence of improved routine clinical diagnosis is lacking. • Other aspects of technology improved images more than field strength. © European Society of Radiology 2012.
Start page
2295
End page
2303
Volume
22
Issue
11
Language
English
OCDE Knowledge area
Neurología clínica Biotecnología relacionada con la salud
Scopus EID
2-s2.0-84870337640
PubMed ID
Source
European Radiology
ISSN of the container
09387994
Sponsor(s)
The SINAPSE Collaboration (Scottish Imaging Network, A Platform for Scientific Excellence, www.sinapse.ac.uk ) is funded by the Scottish Funding Council and supports the salaries of many of the authors. The project did not receive any other specific funding.
Sources of information: Directorio de Producción Científica Scopus