Title
Cobalt phthalocyanine as a biomimetic catalyst in the amperometric quantification of dipyrone using FIA
Date Issued
30 September 2011
Access level
open access
Resource Type
journal article
Author(s)
Boni A.
Wong A.
Dutra R.
State University of São Paulo (UNESP)
Publisher(s)
Elsevier B.V.
Abstract
A biomimetic sensor for the determination of dipyrone was prepared by modifying carbon paste with cobalt phthalocyanine (CoPc), and used as an amperometric detector in a flow injection analysis (FIA) system. The results of cyclic voltammetry experiments suggested that CoPc behaved as a biomimetic catalyst in the electrocatalytic oxidation of dipyrone, which involved the transfer of one electron. The optimized FIA procedure employed a flow rate of 1.5 mL min-1, a 75 μL sample loop, a 0.1 mol L-1 phosphate buffer carrier solution at pH 7.0 and amperometric detection at a potential of 0.3 V vs. Ag/AgCl. Under these conditions, the proposed method showed a linear response for dipyrone concentrations in the range 5.0 × 10-6-6.3 × 10-3 mol L-1. Selectivity and interference studies were carried out in order to validate the system for use with pharmaceutical and environmental samples. In addition to being environmentally friendly, the proposed method is a sensitive and selective analytical tool for the determination of dipyrone. © 2011 Elsevier B.V. All rights reserved.
Start page
2067
End page
2073
Volume
85
Issue
4
Language
English
OCDE Knowledge area
Química analítica
Scopus EID
2-s2.0-80052158357
Source
Talanta
ISSN of the container
00399140
Sponsor(s)
The authors gratefully acknowledge the financial support provided by the São Paulo State Research Foundation (FAPESP , processes 2008/00303-5 and 2009/04598-2 ).
Sources of information: Directorio de Producción Científica Scopus