Title
Performance of the CMS cathode strip chambers with cosmic rays
Date Issued
01 December 2010
Access level
open access
Resource Type
journal article
Author(s)
Chatrchyan S.
Khachatryan V.
Sirunyan A.M.
Adam W.
Arnold B.
Bergauer H.
Bergauer T.
Dragicevic M.
Eichberger M.
Erö J.
Friedl M.
Frühwirth R.
Ghete V.M.
Hammer J.
Hansel S.
Hoch M.
Hörmann N.
Hrubec J.
Jeitler M.
Kasieczka G.
Kastner K.
Krammer M.
Liko D.
De Magrans Abril I.
Mikulec I.
Mittermayr F.
Neuherz B.
Oberegger M.
Padrta M.
Pernicka M.
Rohringer H.
Schmid S.
Schöfbeck R.
Schreiner T.
Stark R.
Steininger H.
Strauss J.
Taurok A.
Teischinger F.
Themel T.
Uhl D.
Wagner P.
Waltenberger W.
Walzel G.
Widl E.
Wulz C.E.
Chekhovsky V.
Dvornikov O.
Emeliantchik I.
Litomin A.
Makarenko V.
Marfin I.
Mossolov V.
Shumeiko N.
Solin A.
Stefanovitch R.
Suarez Gonzalez J.
Tikhonov A.
Fedorov A.
Karneyeu A.
Korzhik M.
Panov V.
Zuyeuski R.
Kuchinsky P.
Beaumont W.
Benucci L.
Cardaci M.
De Wolf E.A.
Delmeire E.
Druzhkin D.
Hashemi M.
Janssen X.
Maes T.
Mucibello L.
Ochesanu S.
Rougny R.
Selvaggi M.
Van Haevermaet H.
Van Mechelen P.
Van Remortel N.
Adler V.
Beauceron S.
Blyweert S.
D'Hondt J.
De Weirdt S.
Devroede O.
Heyninck J.
Kalogeropoulos A.
Maes J.
Maes M.
Mozer M.U.
Tavernier S.
Van Doninck W.
Van Mulders P.
Villella I.
Bouhali O.
Chabert E.C.
Charaf O.
Clerbaux B.
De Lentdecker G.
Yerevan Physics Institute, Yerevan, Armenia
Yerevan Physics Institute, Yerevan, Armenia
Yerevan Physics Institute, Yerevan, Armenia
Institut für Hochenergiephysik der OeAW, Wien, Austria
Institut für Hochenergiephysik der OeAW, Wien, Austria
Institut für Hochenergiephysik der OeAW, Wien, Austria
Institut für Hochenergiephysik der OeAW, Wien, Austria
Institut für Hochenergiephysik der OeAW, Wien, Austria
Institut für Hochenergiephysik der OeAW, Wien, Austria
Institut für Hochenergiephysik der OeAW, Wien, Austria
Institut für Hochenergiephysik der OeAW, Wien, Austria
Institut für Hochenergiephysik der OeAW, Wien, Austria
Publisher(s)
Institute of Physics
Abstract
The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47μm to 243μm. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns. © 2010 IOP Publishing Ltd and SISSA.
Volume
5
Issue
3
Language
English
OCDE Knowledge area
Física de partículas, Campos de la Física
Scopus EID
2-s2.0-79953292228
Source
Journal of Instrumentation
ISSN of the container
17480221
Sources of information: Directorio de Producción Científica Scopus