Title
Dual-modality optical coherence tomography and frequency-domain fluorescence lifetime imaging microscope system for intravascular imaging
Date Issued
01 September 2020
Access level
open access
Resource Type
journal article
Author(s)
Chen X.
Kim W.
Serafino M.J.
Tan Z.
Applegate B.E.
University of Oklahoma
Publisher(s)
SPIE
Abstract
Significance: Detailed biochemical and morphological imaging of the plaque burdened coronary arteries holds the promise of improved understanding of atherosclerosis plaque development, ultimately leading to better diagnostics and therapies. Aim: Development of a dual-modality intravascular catheter supporting swept-source optical coherence tomography (OCT) and frequency-domain fluorescence lifetime imaging (FD-FLIM) of endogenous fluorophores with UV excitation. Approach: We instituted a refined approach to endoscope development that combines simulation in a commercial ray tracing program, fabrication, and a measurement method for optimizing ball-lens performance. With this approach, we designed and developed a dual-modality catheter endoscope based on a double-clad fiber supporting OCT through the core and fluorescence collection through the first cladding. We varied the relative percent of UV excitation launched into the core and first cladding to explore the potential resolution improvement for FD-FLIM. The developed catheter endoscope was optically characterized, including measurement of spatial resolution and fluorescent lifetimes of standard fluorophores. Finally, the system was demonstrated on fresh ex vivo human coronary arteries. Results: The developed endoscope was shown to have optical performance similar to predictions derived from the simulation approach. The FLIM resolution can be improved by over a factor of 4 by primarily illuminating through the core rather than the first cladding. However, time-dependent solarization losses need to be considered when choosing the relative percentage. We ultimately chose to illuminate with 7% of the power transmitting through the core. The resulting catheter endoscope had 40-μm lateral resolution for OCT and <100 μm lateral resolution for FD-FLIM. Images of ex vivo coronary arteries are consistent with expectations based on histopathology. Conclusions: The results demonstrate that our approach for endoscope simulation produces reliable predictions of endoscope performance. Simulation results guided our development of a multimodal OCT/FD-FLIM catheter imaging system for investigating atherosclerosis in coronary arteries.
Volume
25
Issue
9
Number
096010
Language
English
OCDE Knowledge area
Radiología, Medicina nuclear, Imágenes médicas Sistema cardiaco, Sistema cardiovascular Salud pública, Salud ambiental
Scopus EID
2-s2.0-85092413713
PubMed ID
Source
Journal of Biomedical Optics
ISSN of the container
10833668
Sponsor(s)
National Heart, Lung, and Blood Institute - R01HL111361 -NHLBI The research was supported by the U.S. National Institutes of Health No. 5R01HL111361-02.