Implementation and performance evaluation of a reclosing method for shunt reactor-compensated transmission lines
Date Issued
01 April 2011
Access level
metadata only access
Resource Type
journal article
Author(s)
University of Campinas
Abstract
This paper proposes a new control method to reduce overvoltages due to three-phase reclosing for shunt compensated transmission lines (TL). The method detects the first minimum voltage region of the beating across the circuit breakers after protection dead time and works independently of voltage zero crossing, reducing significantly the reclosure time. The controller was tested on a Real Time Digital Simulator (RTDS) and its performance was compared to the traditional preinsertion resistor approach and another existing control method. © 2010 IEEE.
Start page
954
End page
962
Volume
26
Issue
2
Language
English
OCDE Knowledge area
Sistemas de automatización, Sistemas de control
Ingeniería eléctrica, Ingeniería electrónica
Subjects
Scopus EID
2-s2.0-79953202827
Source
IEEE Transactions on Power Delivery
ISSN of the container
08858977
Sponsor(s)
Manuscript received March 22, 2010; revised July 31, 2010; accepted September 12, 2010. Date of publication December 03, 2010; date of current version March 25, 2011. This work was supported in part by a grant from the National Council for Scientific and Technological Development (CNPq), CAPES and FAPESP, Brazil, and in part by the Industrial Research Chair Program of the NSERC, Canada. Paper no. TPWRD-00207-2010.