Title
Biodegradability and toxicity assessment of a real textile wastewater effluent treated by an optimized electrocoagulation process
Date Issued
16 February 2015
Access level
metadata only access
Resource Type
journal article
Author(s)
Manenti D.R.
Módenes A.N.
Soares P.A.
Boaventura R.A.R.
Palácio S.M.
Borba F.H.
Bergamasco R.
Vilar V.J.P.
West Paraná State University
Publisher(s)
Taylor and Francis Ltd.
Abstract
In this work, the application of an iron electrode-based electrocoagulation (EC) process on the treatment of a real textile wastewater (RTW) was investigated. In order to perform an efficient integration of the EC process with a biological oxidation one, an enhancement in the biodegradability and low toxicity of final compounds was sought. Optimal values of EC reactor operation parameters (pH, current density and electrolysis time) were achieved by applying a full factorial 33 experimental design. Biodegradability and toxicity assays were performed on treated RTW samples obtained at the optimal values of: pH of the solution (7.0), current density (142.9Am-2) and different electrolysis times. As response variables for the biodegradability and toxicity assessment, the Zahn-Wellens test (Dt), the ratio values of dissolved organic carbon (DOC) relative to low-molecular-weight carboxylates anions (LMCA) and lethal concentration 50 (LC50) were used. According to the Dt, the DOC/LMCA ratio and LC50, an electrolysis time of 15min along with the optimal values of pH and current density were suggested as suitable for a next stage of treatment based on a biological oxidation process.
Start page
496
End page
506
Volume
36
Issue
4
Language
English
OCDE Knowledge area
Biotecnología ambiental
Investigación climática
Ingeniería ambiental
Subjects
Scopus EID
2-s2.0-84919786907
PubMed ID
Source
Environmental Technology (United Kingdom)
ISSN of the container
09593330
DOI of the container
10.1080/09593330.2014.952676
Source funding
Instituto Nacional de Ciência e Tecnologia para Excitotoxicidade e Neuroproteção
CAPES-BR
Araucaria Foundation-BR
CNPq-BR
QREN
Fundació Catalana de Trasplantament
Programa Operacional Temático Factores de Competitividade
Sponsor(s)
This work was supported by projects PEst-C/EQB/LA0020/2013 and NORTE-07-0162-FEDER-000050, financed by FEDER through COMPETE - Programa Operacional Factores de Com-petitividade, by FCT – Fundação para a Ciência e a Tecnologia and by QREN and ON2. We also would like to thank the Araucaria Foundation-BR, CNPq-BR and CAPES-BR (BEX 9794/11-5 and 5512/10-7 processes) for financial support for this study. V.J.P. Vilar acknowledges the FCT Investigator 2013 Programme (IF/01501/2013).
Sources of information:
Directorio de Producción Científica
Scopus