Title
Continuous glucose monitoring: An endocrine society clinical practice guideline
Date Issued
01 January 2011
Access level
open access
Resource Type
review
Author(s)
Klonoff D.C.
Buckingham B.
Christiansen J.S.
Tamborlane W.V.
Vigersky R.A.
Wolpert H.
Mayo Clinic
Publisher(s)
Endocrine Society
Abstract
Objective: The aim was to formulate practice guidelines for determining settings where patients are most likely to benefit from the use of continuous glucose monitoring (CGM). Participants: The Endocrine Society appointed a Task Force of experts, a methodologist, and a medical writer. Evidence: This evidence-based guideline was developed using the Grading of Recommendations, Assessment, Development, and Evaluation (GRADE) system to describe both the strength of recommendations and the quality of evidence. Consensus Process: One group meeting, several conference calls, and e-mail communications enabled consensus. Committees and members of The Endocrine Society, the Diabetes Technology Society, and the European Society of Endocrinology reviewed and commented on preliminary drafts of these guidelines. Conclusions: The Task Force evaluated three potential uses of CGM: 1) real-time CGM in adult hospital settings; 2) real-time CGM in children and adolescent outpatients; and 3) real-time CGM in adult outpatients. The Task Force used the best available data to develop evidence-based recommendations about where CGM can be beneficial in maintaining target levels of glycemia and limiting the risk of hypoglycemia. Both strength of recommendations and quality of evidence were accounted for in the guidelines. Copyright © 2011 by The Endocrine Society.
Start page
2968
End page
2979
Volume
96
Issue
10
Language
English
OCDE Knowledge area
Políticas de salud, Servicios de salud
Scopus EID
2-s2.0-80053543458
PubMed ID
Source
Journal of Clinical Endocrinology and Metabolism
ISSN of the container
0021972X
Sources of information: Directorio de Producción Científica Scopus